ERROR | POSSIBLE CAUSES | SOLUTION |
CP positive/negative voltage | The voltage on the CP connector is out of permitted range | Check the charging cable and connector and reconnect the electric vehicle |
RCD sensor trip | Switch has detected a DC differential current | If is problem with only one vehicle, please call an authorized vehicle service |
RCD sensor malfunction | RCD is damaged or not connected | Please call service of the charger |
Undervoltage/Overvoltage | The voltage at the input of the charger is out of permitted range | Please call service of the charger |
Charge with ventilation | The vehicle requires charging with ventilation and “Charging with ventilation” is not enabled on the user interface | Enable “Charging with ventilation” on the user interface if the electric vehicle is charged in a ventilated area or outdoor |
PS reading error | There is no connection to the power sensor in the charger housing | Please call service of the charger |
Current is higher than allowed | The vehicle is charged with higer current that is allowed | Try charging another electric vehicle and if the error is still present, please call the charger service. Otherwise, call authorized service of your vehicle |