General description

This section describes standard GRMS room variants used as reference configurations for HIQ Hospitality projects.

Each variant defines a typical guest room automation setup, including the main controller, access control, room panel, HVAC control, lighting, blinds, sensors, communication modules and connection to the central S-RMS system through Linker.

The purpose of these pages is to provide a clear technical overview of available standard room configurations. Detailed wiring, I/O allocation, programming and project-specific adaptations are defined in the corresponding electrical schemes and technical documentation.

Room variant overview

Room variant overview

Variant Page Main controller Main extension Short description
V1 V1 - GRMS Room Base - MC-24-H1 MC-24-H1 Base configuration Base full GRMS room with access control, room panel, ES-W2 temperature sensor, FC-1-IQ, lighting, blinds, sensors and energy-saving logic.
V1.1 V1.1 - GRMS Room Base I/O Plus - MC-24-H1 + LC-10-IQ-MK2 MC-24-H1 LC-10-IQ-MK2 Base room with LC-10-IQ-MK2 module for additional lighting circuits and blinds.
V1.2 V1.2 - GRMS Room Base Modbus - MC-24-H1 + CAD-232-A3-IQ MC-24-H1 CAD-232-A3-IQ Base room with RS485 / Modbus communication for recuperator or compatible HVAC equipment.
V1.3 V1.3 - GRMS Room Full Option - MC-24-H1 + LC-10-IQ-MK2 + CAD-232-A3-IQ MC-24-H1 LC-10-IQ-MK2 + CAD-232-A3-IQ Full option MC-24-H1 room with additional I/O for lighting/blinds and RS485 / Modbus communication.
V2 V2 - GRMS Room Direct HVAC - MC-24-H1 MC-24-H1 Direct HVAC outputs Simplified MC-24-H1 variant where controller outputs are used directly for HVAC control.
V3 V3 - GRMS Room Compact Modbus - MC-230-01 MC-230-01 Integrated RS485 Compact room variant with integrated RS485 / Modbus and direct IEX connection.
V3.1 V3.1 - GRMS Room Compact Wireless - MC-230-01 + EnOcean MC-230-01 Integrated RS485 + EnOcean Compact MC-230-01 room variant with RS485 and SWO-2-1-00 EnOcean wireless opening sensor.

Typical connected functions

Standard GRMS room variants can include the following functional groups:

  • room access control
  • door lock and door status
  • in-room touch panel with TGP-S adapter
  • ES-W2 room temperature sensor
  • HVAC / fan-coil control
  • lighting control
  • blinds control
  • window contact monitoring
  • presence detection
  • SOS / alarm input
  • master off / room exit scene
  • floor heating
  • ventilation
  • managed power supply for energy-saving logic
  • Ethernet / Linker connection to S-RMS

Notes

  • These variants represent standard reference configurations.
  • Final I/O allocation may be adjusted according to room type and project requirements.
  • Electrical schemes and controller programs should be prepared based on the selected variant.
  • Additional variants can be added if required by future project configurations.