* HEMS Configurator -> limiter -> set "No limiter" | * HEMS Configurator -> limiter -> set "No limiter" | ||
- | {{wiki:rdx_charger: | + | {{wiki:20_rdc_charger: |
=== Procedure to set RDX Charger as master is as follows: === | === Procedure to set RDX Charger as master is as follows: === | ||
* [[wiki: | * [[wiki: | ||
- | {{wiki:rdx_charger: | + | {{wiki:20_rdc_charger: |
* HEMS Configurator -> settings -> enter name and select icon (2). Message "Error - device is not responding" | * HEMS Configurator -> settings -> enter name and select icon (2). Message "Error - device is not responding" | ||
- | {{wiki:rdx_charger: | + | {{wiki:20_rdc_charger: |
* HEMS Configurator -> limiter: | * HEMS Configurator -> limiter: | ||
* (3) enter allowed current value of grid fuses in case of connected grid power sensor, or max current limit of complete ev fleet if there is virtual grid active | * (3) enter allowed current value of grid fuses in case of connected grid power sensor, or max current limit of complete ev fleet if there is virtual grid active | ||
* (4) make sure to configure phase order for grid and RDX Chargers correct as dynamic load management may not work properly. **Double check!** | * (4) make sure to configure phase order for grid and RDX Chargers correct as dynamic load management may not work properly. **Double check!** | ||
* (5) select limiter priority for chargers: no limiter, limit last (last to be limited), limit second, limit first (first to be limited) | * (5) select limiter priority for chargers: no limiter, limit last (last to be limited), limit second, limit first (first to be limited) | ||
- | {{wiki:rdx_charger: | + | {{wiki:20_rdc_charger: |
* HEMS Configurator -> IO mux -> enter IP address of slave RDX Charger (6). Serial number (SN) will be listed automatically once connection is established. | * HEMS Configurator -> IO mux -> enter IP address of slave RDX Charger (6). Serial number (SN) will be listed automatically once connection is established. | ||
- | {{wiki:rdx_charger: | + | {{wiki:20_rdc_charger: |
* HEMS Configurator -> ev fleet:\\ (7) master RDX Charger,\\ (8) connected slave RDX Charger with enabled control by master (green tick) and\\ (9) connected slave RDX Charger with disabled control (red X) -> master can not control it! To enable control, run RDX Charger app on slave charger and enable "EVSE works as slave" | * HEMS Configurator -> ev fleet:\\ (7) master RDX Charger,\\ (8) connected slave RDX Charger with enabled control by master (green tick) and\\ (9) connected slave RDX Charger with disabled control (red X) -> master can not control it! To enable control, run RDX Charger app on slave charger and enable "EVSE works as slave" | ||
- | {{wiki:rdx_charger: | + | {{wiki:20_rdc_charger: |