 === Procedure to set RDX Charger as slave is as follows: === === Procedure to set RDX Charger as slave is as follows: ===
-  * [[wiki:20_rdc_charger:06_software:start#evse_overview|RDX Charger]] -> set Max current (1)+  * [[wiki:20_rdc_charger:30_software:start#evse_overview|RDX Charger]] -> set Max current (1)
   * RDX Charger -> enable "EVSE works as slave" (2) Master SN presents serial number of master charger, it will appear once connection is established.    * RDX Charger -> enable "EVSE works as slave" (2) Master SN presents serial number of master charger, it will appear once connection is established. 
   * RDX Charger -> set current if connection with master is lost (3)   * RDX Charger -> set current if connection with master is lost (3)
-  * [[wiki:20_rdc_charger:06_software:start#hems_configurator|HEMS Configurator]] -> settings -> set static IP (it's recommended) (4)+  * [[wiki:20_rdc_charger:30_software:start#hems_configurator|HEMS Configurator]] -> settings -> set static IP (it's recommended) (4)
   * HEMS Configurator -> limiter -> set "No limiter" for RDX Charger (5)   * HEMS Configurator -> limiter -> set "No limiter" for RDX Charger (5)
-{{wiki:rdx_charger:hems_config_cluster_01.png?direct&800|}}+{{wiki:20_rdc_charger:hems_config_cluster_01.png?direct&800|}}
  
 === Procedure to set RDX Charger as master is as follows: === === Procedure to set RDX Charger as master is as follows: ===
-  * [[wiki:20_rdc_charger:06_software:start#hems_configurator|HEMS Configurator]] -> settings -> output column -> select "EVSE RDX external" at desired position (1). Note that "EVSE inter." is reserved and can't be changed!  +  * [[wiki:20_rdc_charger:30_software:start#hems_configurator|HEMS Configurator]] -> settings -> output column -> select "EVSE RDX external" at desired position (1). Note that "EVSE inter." is reserved and can't be changed!  
-{{wiki:rdx_charger:hems_config_cluster_02.png?direct&800|}}+{{wiki:20_rdc_charger:hems_config_cluster_02.png?direct&800|}}
   * HEMS Configurator -> settings -> enter name and select icon (2). Message "Error - device is not responding" may appear as IP address is not defined yet.   * HEMS Configurator -> settings -> enter name and select icon (2). Message "Error - device is not responding" may appear as IP address is not defined yet.
-{{wiki:rdx_charger:hems_config_cluster_03.png?direct&800|}}+{{wiki:20_rdc_charger:hems_config_cluster_03.png?direct&800|}}
   * HEMS Configurator -> limiter:    * HEMS Configurator -> limiter: 
   * (3) enter allowed current value of grid fuses in case of connected grid power sensor, or max current limit of complete ev fleet if there is virtual grid active   * (3) enter allowed current value of grid fuses in case of connected grid power sensor, or max current limit of complete ev fleet if there is virtual grid active
   * (4) make sure to configure phase order for grid and RDX Chargers correct as dynamic load management may not work properly. **Double check!**   * (4) make sure to configure phase order for grid and RDX Chargers correct as dynamic load management may not work properly. **Double check!**
   * (5) select limiter priority for chargers: no limiter, limit last (last to be limited), limit second, limit first (first to be limited)   * (5) select limiter priority for chargers: no limiter, limit last (last to be limited), limit second, limit first (first to be limited)
-{{wiki:rdx_charger:hems_config_cluster_04.png?direct&800|}}+{{wiki:20_rdc_charger:hems_config_cluster_04.png?direct&800|}}
   * HEMS Configurator -> IO mux -> enter IP address of slave RDX Charger (6). Serial number (SN) will be listed automatically once connection is established.   * HEMS Configurator -> IO mux -> enter IP address of slave RDX Charger (6). Serial number (SN) will be listed automatically once connection is established.
-{{wiki:rdx_charger:hems_config_cluster_05.png?direct&800|}}+{{wiki:20_rdc_charger:hems_config_cluster_05.png?direct&800|}}
   * HEMS Configurator -> ev fleet:\\ (7) master RDX Charger,\\ (8) connected slave RDX Charger with enabled control by master (green tick) and\\ (9) connected slave RDX Charger with disabled control (red X) -> master can not control it! To enable control, run RDX Charger app on slave charger and enable "EVSE works as slave".   * HEMS Configurator -> ev fleet:\\ (7) master RDX Charger,\\ (8) connected slave RDX Charger with enabled control by master (green tick) and\\ (9) connected slave RDX Charger with disabled control (red X) -> master can not control it! To enable control, run RDX Charger app on slave charger and enable "EVSE works as slave".
-{{wiki:rdx_charger:hems_config_cluster_06.png?direct&800|}}\\ +{{wiki:20_rdc_charger:hems_config_cluster_06.png?direct&800|}}\\ 