wiki:20_rdc_charger:35_commissioning:06_ev_fleet [2023/03/31 10:07] – ↷ Page moved from wiki:20_rdc_charger:07_commissioning:06_ev_fleet to wiki:20_rdc_charger:35_commissioning:06_ev_fleet saso.santelj | wiki:20_rdc_charger:35_commissioning:06_ev_fleet [2023/05/26 13:04] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 6: | Line 6: | ||
Master RDX Charger monitors:\\ | Master RDX Charger monitors:\\ | ||
* current draw by other slave chargers and in real time allocates (limits) available capacity allowing them to charge without overloading, | * current draw by other slave chargers and in real time allocates (limits) available capacity allowing them to charge without overloading, | ||
- | * data from slaves such as power, energy & settings and synchronize them with cloud service, therefore no need for extra [[wiki: | + | * data from slaves such as power, energy & settings and synchronize them with cloud service, therefore no need for extra [[wiki: |
**Note:** If there is no grid power sensor, master charger enables limiting of complete ev fleet by virtual grid power sensor.\\ | **Note:** If there is no grid power sensor, master charger enables limiting of complete ev fleet by virtual grid power sensor.\\ | ||
:!: Only one RDX charger is master in ev fleet ! | :!: Only one RDX charger is master in ev fleet ! | ||
=== Procedure to set RDX Charger as slave is as follows: === | === Procedure to set RDX Charger as slave is as follows: === | ||
- | * [[wiki: | + | * [[wiki: |
* RDX Charger -> enable "EVSE works as slave" (2) Master SN presents serial number of master charger, it will appear once connection is established. | * RDX Charger -> enable "EVSE works as slave" (2) Master SN presents serial number of master charger, it will appear once connection is established. | ||
* RDX Charger -> set current if connection with master is lost (3) | * RDX Charger -> set current if connection with master is lost (3) | ||
- | * [[wiki: | + | * [[wiki: |
* HEMS Configurator -> limiter -> set "No limiter" | * HEMS Configurator -> limiter -> set "No limiter" | ||
- | {{wiki:rdx_charger: | + | {{wiki:20_rdc_charger: |
=== Procedure to set RDX Charger as master is as follows: === | === Procedure to set RDX Charger as master is as follows: === | ||
- | * [[wiki: | + | * [[wiki: |
- | {{wiki:rdx_charger: | + | {{wiki:20_rdc_charger: |
* HEMS Configurator -> settings -> enter name and select icon (2). Message "Error - device is not responding" | * HEMS Configurator -> settings -> enter name and select icon (2). Message "Error - device is not responding" | ||
- | {{wiki:rdx_charger: | + | {{wiki:20_rdc_charger: |
* HEMS Configurator -> limiter: | * HEMS Configurator -> limiter: | ||
* (3) enter allowed current value of grid fuses in case of connected grid power sensor, or max current limit of complete ev fleet if there is virtual grid active | * (3) enter allowed current value of grid fuses in case of connected grid power sensor, or max current limit of complete ev fleet if there is virtual grid active | ||
* (4) make sure to configure phase order for grid and RDX Chargers correct as dynamic load management may not work properly. **Double check!** | * (4) make sure to configure phase order for grid and RDX Chargers correct as dynamic load management may not work properly. **Double check!** | ||
* (5) select limiter priority for chargers: no limiter, limit last (last to be limited), limit second, limit first (first to be limited) | * (5) select limiter priority for chargers: no limiter, limit last (last to be limited), limit second, limit first (first to be limited) | ||
- | {{wiki:rdx_charger: | + | {{wiki:20_rdc_charger: |
* HEMS Configurator -> IO mux -> enter IP address of slave RDX Charger (6). Serial number (SN) will be listed automatically once connection is established. | * HEMS Configurator -> IO mux -> enter IP address of slave RDX Charger (6). Serial number (SN) will be listed automatically once connection is established. | ||
- | {{wiki:rdx_charger: | + | {{wiki:20_rdc_charger: |
* HEMS Configurator -> ev fleet:\\ (7) master RDX Charger,\\ (8) connected slave RDX Charger with enabled control by master (green tick) and\\ (9) connected slave RDX Charger with disabled control (red X) -> master can not control it! To enable control, run RDX Charger app on slave charger and enable "EVSE works as slave" | * HEMS Configurator -> ev fleet:\\ (7) master RDX Charger,\\ (8) connected slave RDX Charger with enabled control by master (green tick) and\\ (9) connected slave RDX Charger with disabled control (red X) -> master can not control it! To enable control, run RDX Charger app on slave charger and enable "EVSE works as slave" | ||
- | {{wiki:rdx_charger: | + | {{wiki:20_rdc_charger: |