wiki:20_rdc_charger:35_commissioning:05_dlm

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
wiki:20_rdc_charger:35_commissioning:05_dlm [2023/03/31 10:54] – ↷ Links adapted because of a move operation goran.kocjancicwiki:20_rdc_charger:35_commissioning:05_dlm [2023/08/02 13:47] (current) saso.santelj
Line 2: Line 2:
  
  
-RDX charger supports power consumption (current draw) control to prevent circuit breaker tripping (overloading). \\+RDC Charger supports power consumption (current draw) control to prevent circuit breaker tripping (overloading). \\
 Overloading causes multiple high-energy appliances working at the same time, such as an oven, dishwasher, heat pump and EV charging.\\  Overloading causes multiple high-energy appliances working at the same time, such as an oven, dishwasher, heat pump and EV charging.\\ 
-RDX Charger monitors a current draw by appliances and in real time allocates (limits) available capacity allowing them to run without overloading.\\  +RDC Charger monitors a current draw by appliances and in real time allocates (limits) available capacity allowing them to run without overloading.\\  
-**NOTE**: Power sensor must be mounted so that it can measure power & current on grid (power supply for object/home).+**NOTE**: Power sensor must be mounted so that it can measure power & current on grid (power supply for home/facility).
  
 Procedure to activate Dynamic Load Management is as follows: Procedure to activate Dynamic Load Management is as follows:
   * [[wiki:20_rdc_charger:30_software:start#hems_configurator|HEMS Configurator]] -> settings -> Virtual grid PS must be disabled (1)   * [[wiki:20_rdc_charger:30_software:start#hems_configurator|HEMS Configurator]] -> settings -> Virtual grid PS must be disabled (1)
-  * Wire [[wiki:20_rdc_charger:15_hardware:20_pm1|PM1-E-D]] or [[wiki:20_rdc_charger:15_hardware:21_pm3|PM3-E-D]] to [[wiki:20_rdc_charger:25_wiring:start#wireless_power_sensors_wiring|WM-1]] module  +  * Wire [[wiki:20_rdc_charger:15_hardware:20_pm1|PM1-E-D]] or [[wiki:20_rdc_charger:15_hardware:21_pm3|PM3-E-D]] to [[wiki:20_rdc_charger:25_wiring:start#wireless_power_sensors_wiring|WM-1]] module (use default address 149 or manually set address to 150) 
-  * HEMS Configurator -> settings -> select WM/WR binding button and follow [[wiki:20_rdc_charger:35_commissioning:03_wr_wm|WM/WR binding instructions]] (2) (3)+  * HEMS Configurator -> settings -> select WM/WR pairing button and follow [[wiki:20_rdc_charger:35_commissioning:03_wr_wm|WM/WR pairing instructions]] (2) (3)
 {{wiki:20_rdc_charger:hems_config_dynamic_01.png?direct&800|}} {{wiki:20_rdc_charger:hems_config_dynamic_01.png?direct&800|}}
   * Power sensor is detected. Add it to grid position (4)   * Power sensor is detected. Add it to grid position (4)
Line 16: Line 16:
   * Power sensor configured successfully (5)   * Power sensor configured successfully (5)
 {{wiki:20_rdc_charger:hems_config_dynamic_03.png?direct&800|}} {{wiki:20_rdc_charger:hems_config_dynamic_03.png?direct&800|}}
-  * HEMS Configurator -> dlm, enter allowed current value of grid fuses (6) +  * HEMS Configurator -> DLM, enter allowed current value of grid fuses (6) 
-  * make sure to configure phase order (7) correct, otherwise dynamic load management may not work properly +  * make sure to configure correct phase order (7), otherwise dynamic load management may not work properly 
-  * select limiter priority for RDX Charger (8): no limiter, limit last (last to be limited), limit second, limit first (first to be limited)+  * select limiter priority for RDC Charger (8): no limiter, limit last (last to be limited), limit second, limit first (first to be limited)
 {{wiki:20_rdc_charger:hems_config_dynamic_04.png?direct&800|}} {{wiki:20_rdc_charger:hems_config_dynamic_04.png?direct&800|}}
  