 :!: Only one RDC charger is master in ev fleet ! :!: Only one RDC charger is master in ev fleet !
  
-=== Procedure to set RDX Charger as slave is as follows: ===+=== Procedure to set RDC Charger as slave is as follows: ===
   * [[wiki:20_rdc_charger:30_software:start#evse_overview|RDC Charger]] -> set Max current (1)   * [[wiki:20_rdc_charger:30_software:start#evse_overview|RDC Charger]] -> set Max current (1)
   * RDC Charger -> enable "EVSE works as slave" (2) Master SN presents serial number of master charger, it will appear once connection is established.    * RDC Charger -> enable "EVSE works as slave" (2) Master SN presents serial number of master charger, it will appear once connection is established. 
   * RDC Charger -> set current if connection with master is lost (3)   * RDC Charger -> set current if connection with master is lost (3)
   * [[wiki:20_rdc_charger:30_software:start#hems_configurator|HEMS Configurator]] -> settings -> set static IP (it's recommended) (4)   * [[wiki:20_rdc_charger:30_software:start#hems_configurator|HEMS Configurator]] -> settings -> set static IP (it's recommended) (4)
-  * HEMS Configurator -> limiter -> set "No limiter" for RDX Charger (5)+  * HEMS Configurator -> limiter -> set "No limiter" for RDC Charger (5)
 {{wiki:20_rdc_charger:hems_config_cluster_01.png?direct&800|}} {{wiki:20_rdc_charger:hems_config_cluster_01.png?direct&800|}}
  
Line 28: Line 28:
   * (5) select limiter priority for chargers: no limiter, limit last (last to be limited), limit second, limit first (first to be limited)   * (5) select limiter priority for chargers: no limiter, limit last (last to be limited), limit second, limit first (first to be limited)
 {{wiki:20_rdc_charger:hems_config_cluster_04.png?direct&800|}} {{wiki:20_rdc_charger:hems_config_cluster_04.png?direct&800|}}
-  * HEMS Configurator -> IO mux -> enter IP address of slave RDX Charger (6). Serial number (SN) will be listed automatically once connection is established.+  * HEMS Configurator -> IO mux -> enter IP address of slave RDC Charger (6). Serial number (SN) will be listed automatically once connection is established.
 {{wiki:20_rdc_charger:hems_config_cluster_05.png?direct&800|}} {{wiki:20_rdc_charger:hems_config_cluster_05.png?direct&800|}}
-  * HEMS Configurator -> ev fleet:\\ (7) master RDC Charger,\\ (8) connected slave RDX Charger with enabled control by master (green tick) and\\ (9) connected slave RDC Charger with disabled control (red X) -> master can not control it! To enable control, run RDC Charger app on slave charger and enable "EVSE works as slave".+  * HEMS Configurator -> ev fleet:\\ (7) master RDC Charger,\\ (8) connected slave RDC Charger with enabled control by master (green tick) and\\ (9) connected slave RDC Charger with disabled control (red X) -> master can not control it! To enable control, run RDC Charger app on slave charger and enable "EVSE works as slave".
 {{wiki:20_rdc_charger:hems_config_cluster_06.png?direct&800|}}\\  {{wiki:20_rdc_charger:hems_config_cluster_06.png?direct&800|}}\\ 