User Tools

Site Tools


wiki:20_rdc_charger:35_commissioning:01_power_sensor

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
wiki:20_rdc_charger:35_commissioning:01_power_sensor [2023/03/31 10:07] – ↷ Links adapted because of a move operation saso.santeljwiki:20_rdc_charger:35_commissioning:01_power_sensor [2025/06/11 12:08] (current) saso.santelj
Line 1: Line 1:
 ====== Power sensor adding ====== ====== Power sensor adding ======
  
-{{wiki:rdx_charger:hems_add_ps.png?direct&600}}\\+{{wiki:20_rdc_charger:hems_add_ps.png?direct&600}}\\
  
 :!: Adding is supported one by one\\ :!: Adding is supported one by one\\
-:!: Before adding or removing power sensor via wireless [[wiki:20_rdc_charger:15_hardware:22_wm-1|WM-1]] module, button [[wiki:20_rdc_charger:06_software:start#settings|Settings page]] -> **Scan w-less dev.** must be active!\\+:!: Before adding or removing power sensor via wireless [[wiki:20_rdc_charger:15_hardware:22_wm-1|WM-1]] module, button [[wiki:20_rdc_charger:30_software:start#settings|Settings page]] -> **Scan w-less dev.** must be active!\\
  
   *   Connect communication bus (to only one power sensor)   *   Connect communication bus (to only one power sensor)
   *   Only for PM1-E-D: Press and hold the push-button on the power sensor until it appears **-SEt-** on display   *   Only for PM1-E-D: Press and hold the push-button on the power sensor until it appears **-SEt-** on display
-  *   In [[wiki:20_rdc_charger:06_software:start#settings|HEMS Configurator]] power sensor should appear as a **new device**+  *   In [[wiki:20_rdc_charger:30_software:start#settings|HEMS Configurator]] power sensor should appear as a **new device**
   *   Click on the **add** button next to the source or consumer to which sensor is measuring   *   Click on the **add** button next to the source or consumer to which sensor is measuring
   *   Connect communication bus to the next power sensor and repeat procedure   *   Connect communication bus to the next power sensor and repeat procedure
Line 18: Line 18:
 <WRAP column 350px> <WRAP column 350px>
 ^ Address ^ Power sensor position| ^ Address ^ Power sensor position|
-| 149 | Default (new PS) appears in field **new device**  |+1, 149 | Default (new PS) appears in field **new device**  |
 | 150 | Grid  | | 150 | Grid  |
 | 154,155,156 | Power plants  | | 154,155,156 | Power plants  |
Line 27: Line 27:
 <WRAP column 450px> <WRAP column 450px>
  
-{{wiki:rdx_charger:ps_position.png?direct&300|}}+{{wiki:20_rdc_charger:ps_position.png?direct&300|}}
  
 </WRAP> </WRAP>
Line 33: Line 33:
 ==== Power sensor removing ==== ==== Power sensor removing ====
  
-{{wiki:rdx_charger:hems_del_ps.png?direct&600}}+{{wiki:20_rdc_charger:hems_del_ps.png?direct&600}}
  
   * Make sure the **new device** is empty (as on image above)   * Make sure the **new device** is empty (as on image above)
   * Only for PM1-E-D: Press the button on power sensor until **-Set-** appears on the display   * Only for PM1-E-D: Press the button on power sensor until **-Set-** appears on the display
-  * In [[wiki:20_rdc_charger:06_software:start#settings|HEMS Configurator]] press **del** button next to the sensor+  * In [[wiki:20_rdc_charger:30_software:start#settings|HEMS Configurator]] press **del** button next to the sensor
   * After a few seconds, the sensor should appear as a **new device**   * After a few seconds, the sensor should appear as a **new device**
   * The sensor can be removed or it can be assigned to another device   * The sensor can be removed or it can be assigned to another device
Line 43: Line 43:
 ==== Without grid power sensor ==== ==== Without grid power sensor ====
  
-  *   [[wiki:20_rdc_charger:06_software:start#settings|Settings]] -> **Virtual grid PS** is an option if no grid meter is used. Power, current and energy will be calculated from other power sensors.+  *   [[wiki:20_rdc_charger:30_software:start#settings|Settings]] -> **Virtual grid PS** is an option if no grid meter is used. Power, current and energy will be calculated from other power sensors.
  
wiki/20_rdc_charger/35_commissioning/01_power_sensor.1680257278.txt.gz · Last modified: (external edit)