User Tools

Site Tools


wiki:20_rdc_charger:15_hardware:20_pm1

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
wiki:20_rdc_charger:15_hardware:20_pm1 [2023/03/31 10:07] – ↷ Page moved from wiki:20_rdc_charger:03_hardware:20_pm1 to wiki:20_rdc_charger:15_hardware:20_pm1 saso.santeljwiki:20_rdc_charger:15_hardware:20_pm1 [2023/11/24 12:33] (current) – removed saso.santelj
Line 1: Line 1:
-====== Single phase power-sensor ====== 
  
-**Single phase power-sensor** 
- 
-<WRAP column 350px> 
- 
-{{  :wiki:rdx_charger:03_hardware:pm1-e-d.png?nolink  |}} 
- 
-</WRAP> 
- 
-<WRAP column 300px> 
- 
-| Model number:  ^ PM1-E-D                                           ^ 
-| Connect to:    | [[wiki:20_rdc_charger:03_hardware:01_rdx_charger]]  | 
-| :::            | RS485 power sensor bus \\ A - B                   | 
-| Mounting:      | DIN rail, 1M, 18 mm                               | 
-| Dimensions:    | 18 × 62 × 119 mm                                  | 
- 
-^ Used for measuring power and energy of                 || 
-| ✔ | single-phase energy sources                        | 
-| ✔ | single-phase energy consumers                      | 
- 
-</WRAP> 
- 
-<WRAP clear></WRAP> 
- 
-===== Applications ===== 
- 
-  * Digital multi-function power-sensor for single phase networks 
- 
-===== Features ===== 
- 
-  * DIN rail mounting with direct connection up to 45A 
-  * Compact design in a single module 18mm wide 
-  * Seal-able cover(phase and neutral terminals) 
- 
-===== General description ===== 
- 
- 
-The PM1-E-D series is an advanced single phase energy monitoring solution with built-in configuration push button and LCD data display. Particularly indicated for metering active energy and other power parameters. Housing for DIN-rail mounting, IP51 protection degree, direct connection up to max 45A. 
- 
-<WRAP pagebreak></WRAP> 
- 
-===== Technical specifications ===== 
- 
-|< 40% 50% >| 
-^ Energy Measurements                                                                 || 
-| Imported/Exported active energy            |                       0 to 99999.99 kWh | 
-| Imported/Exported reactive energy          |                     0 to 99999.99 kVArh | 
-| Total active energy                        |                       0 to 99999.99 kWh | 
-| Total reactive energy                      |                     0 to 99999.99 kVArh | 
-^ Measured Inputs                                                                     || 
-| Nominal Voltage Input                      |                      (Ph+N) 176 to 276V | 
-| Max Continuous Voltage                                             120% of nominal | 
-| Nominal Input Current                      |                                  5(45)A | 
-| Max Continuous Current                                             120% of nominal | 
-| Frequency                                  |                             50Hz (±10%) | 
-^ Accuracy                                                                            || 
-| Voltage                                    |                   0·5% of range maximum | 
-| Current                                    |                         0·5% of nominal | 
-| Frequency                                  |                   0·2% of mid-frequency | 
-| Power factor                                                    1% of unity (0.01) | 
-| Active power (W)                                              ±1% of range maximum | 
-| Reactive power (VAr)                                          ±1% of range maximum | 
-| Apparent power (VA)                        |                    ±1% of range maximum | 
-| Active energy (Wh)                                            Class 1 IEC 62053-21 | 
-| Reactive energy (VARh)                                        ±1% of range maximum | 
-^ Modbus (RS485 Output for Modbus RTU & Pulsed Output)                                || 
-| Baud rate                                  |                 1200, 2400, 4800, 9600. | 
-| Parity                                                           none / odd / even | 
-| Stop bits                                  |                                  1 or 2 | 
-| RS485 network address                      |                                1 to 247 | 
-^ Reference Conditions of Influence Quantities                                         || 
-| Ambient temperature                        |                               23°C ±1°C | 
-| Input waveform                                                      50 or 60Hz ±2% | 
-| Input waveform                              Sinusoidal (distortion factor < 0·005) | 
-| Auxiliary supply voltage                                               Nominal ±1% | 
-| Auxiliary supply frequency                                             Nominal ±1% | 
-| Auxiliary supply waveform (if AC)          |   Sinusoidal (distortion factor < 0·05) | 
-| Magnetic field of external origin          |                         Terrestrial flux | 
-^ Environment                                                                         || 
-| Operating temperature                      |                          -25°C to +55°C | 
-| Storage temperature                        |                          -40°C to +70°C | 
-| Relative humidity                          |                0 to 95%, non-condensing | 
-| Altitude                                                               Up to 3000m | 
-| Warm up time                                                              1 minute | 
-| Vibration                                  |         10Hz to 50Hz, IEC 60068-2-6, 2g | 
-| Shock                                      |                         30g in 3 planes | 
-^ Mechanics                                                                           || 
-| DIN rail dimensions                        |         18mm x 90mm (WxH) per DIN 43880 | 
-| Mounting                                                      DIN rail (DIN 43880) | 
- 
-===== PM1-E-D Wiring ===== 
- 
-{{:wiki:rdx_charger:03_hardware:pm1_terminals.png?nolink|}} 
- 
-{{ :wiki:rdx_charger:03_hardware:hiq_pm1-e-d_user_manual_2020.pdf |}}  
- 
-{{ :wiki:rdx_charger:03_hardware:hiq_pm1-e-d-modbus_protocol_v2.2.pdf |}} 
wiki/20_rdc_charger/15_hardware/20_pm1.1680257277.txt.gz · Last modified: (external edit)