wiki:02_hiq-hotel:01_grms:03_s-rms:start [2024/09/03 11:21] – removed - external edit (Unknown date) 127.0.0.1wiki:02_hiq-hotel:01_grms:03_s-rms:start [2024/09/03 11:21] (current) – ↷ Page name changed from wiki:02_hiq-hotel:01_grms:03_s-rms:main to wiki:02_hiq-hotel:01_grms:03_s-rms:start goran.kocjancic
Line 1: Line 1:
 +====== S-RMS ======
 +
 +S-RMS is WEB application on IOT Linker.
 +
 +The S-RMS application can be accessed via any web browser. 
 +
 +Access is always possible via the local network (via the IP address of the IOT Linker). 
 +
 +For remote access via the Internet, it is necessary to allow the WEB-SSH functionality. In this case, the IOT-Linker connects to Robotina's "hiq-space.com" WEB-SSH server via a secure SSH connection. On WEB-SSH server each IOT Linker gets its own web address of the type https://12345.hiq-space.com (12345 is the serial number of the IOT Linker). This makes it possible to access the WEB interface via a secure https connection via the Internet without directly exposing the IOT LInker to the Internet.
 +
 +===== Log-in =====
 +
 +<WRAP group>
 +<WRAP 1000px column>
 +
 +{{ :wiki:02_hiq-hotel:01_grms_iq:srms-login.svg |}}
 +
 +</WRAP>
 +
 +<WRAP column>
 +\\ 
 +Enter Username, Password and press Log in button.
 +
 +</WRAP>
 +</WRAP>
 +
 +===== Room group overview =====
 +
 +<WRAP group>
 +<WRAP 1000px column>
 +
 +{{ :wiki:02_hiq-hotel:01_grms_iq:srms-room_group.svg |}}
 +
 +</WRAP>
 +
 +<WRAP column>
 +\\ 
 +|<300px 50px >|
 +^  1  | Application logo (customizable)                                                     |
 +^  2  | Pages tabs (pages that are available for the selected space in the tree structure)  |
 +^  3  | User menu (user logout and help)                                                    |
 +^  4  | Tree view (room groups and rooms)                                                   |
 +^  5  | Group picture (floor plan, logo, ...)                                               |
 +^  6  | Rooms overview table (basic room statuses)                                          |
 +
 +</WRAP>
 +</WRAP>
 +
 +
 +
 +===== Room overview =====
 +
 +<WRAP group>
 +<WRAP 1000px column>
 +
 +{{ :wiki:02_hiq-hotel:01_grms_iq:s-rms_room.svg |}}
 +
 +</WRAP>
 +
 +<WRAP column>
 +\\ 
 +|<300px 50px >|
 +^  1   | Booked status (click to toggle)                                           |
 +^  2   | Presence status (click to toggle)                                         |
 +^  3   | DND status (click to toggle)                                              |
 +^  4   | MUR status (click to toggle)                                              |
 +^  5   | SOS status (click to toggle)                                              |
 +^  6   | Fire alert status (click to toggle)                                       |
 +^  7   | Managed power supply status (click to toggle)                             |
 +^  8   | Ventilation status (click to toggle)                                      |
 +^  9   | Wake up status (click on icon to toggle, click on time to set time)       |
 +^  10  | Wake-up scene enable (click to toggle)                                    |
 +^  11  | Light status (click to toggle)                                            |
 +^  12  | Dimmer status (click on icon to toggle, set slider to adjust brightness)  |
 +^  13  | Blinds status (set slider to move, click on icon to stop)                 |
 +^  14  | Scene status (click to toggle)                                            |
 +^  15  | HVAC mode (click to set OFF/Heating/Cooling)                              |
 +^  16  | HVAC status (read only)                                                   |
 +^  17  | HVAC measured temperature (read only)                                     |
 +^  18  | HVAC fan speed (read only)                                                |
 +^  19  | HVAC setpoints (click on value to edit)                                   |
 +
 +</WRAP>
 +</WRAP>
 +
 +===== Room access =====
 +
 +<WRAP group>
 +<WRAP 1000px column>
 +
 +{{ :wiki:02_hiq-hotel:01_grms_iq:s-rms_access.svg |}}
 +
 +</WRAP>
 +
 +<WRAP column>
 +
 +\\ 
 +|<300px 50px >|
 +^  1  | Click to add new access code                                      |
 +^  2  | Access codes table. Click in row to select existing access code.  |
 +
 +</WRAP>
 +</WRAP>
 +
 +<WRAP group>
 +<WRAP 1000px column>
 +
 +{{ :wiki:02_hiq-hotel:01_grms_iq:s-rms_acces_sel.svg |}}
 +
 +</WRAP>
 +
 +<WRAP column>
 +
 +\\ 
 +|<300px 50px >|
 +^  1  | Selected access code                                                                      |
 +^  2  | Click to delete selected access code                                                      |
 +^  3  | Click to generate QR code for selected access code.                                       |
 +^  4  | Selected access code details. Click on Edit button to edit selected access code details.  |
 +
 +</WRAP>
 +</WRAP>
 +
 +<WRAP group>
 +<WRAP 1000px column>
 +
 +{{ :wiki:02_hiq-hotel:01_grms_iq:s-rms_access_qr.svg |}}
 +
 +</WRAP>
 +
 +<WRAP column>
 +
 +\\ 
 +|<300px 50px >|
 +^  1  | Generated access code. Copy image and paste to send code to guest or employee  |
 +
 +</WRAP>
 +</WRAP>
 +
 +<WRAP group>
 +<WRAP 1000px column>
 +
 +{{ :wiki:02_hiq-hotel:01_grms_iq:s-rms_access_new.svg |}}
 +</WRAP>
 +
 +<WRAP column>
 +
 +\\ 
 +|<300px 50px >|
 +^  1  | Click to enter custom access code. Always add custom access code for phisical RFID cards.                                                                                                                                                                                                                                                           |
 +^  2  | Manual access code field.                                                                                                                                                                                                                                                                                                                           |
 +^  3  | Access code label.                                                                                                                                                                                                                                                                                                                                  |
 +^  4  | Select access code type. The available code types are set for each room separately in the settings.                                                                                                                                                                                                                                                 |
 +^  5  | Date / time when the access code becomes valid.                                                                                                                                                                                                                                                                                                     |
 +^  6  | Date / time when the access code expires.                                                                                                                                                                                                                                                                                                           |
 +^  7  | Choose if the access code has no time to become valid. Such a code is valid from the moment of entry.                                                                                                                                                                                                                                               |
 +^  8  | Choose if the code has no expiration limit. Such a code will be valid until deleted.                                                                                                                                                                                                                                                                |
 +^  9  | Table of permissions for the selected access code. The list of available access points is set for each room separately in the settings. Each access point can have a limited number of accesses or it can be unlimited. The access point can also be a charging station for electric cars, where the amount of electricity available (kWh) is set.  |
 +
 +</WRAP>
 +</WRAP>
 +
 +===== Search codes =====
 +
 +<WRAP group>
 +<WRAP 1000px column>
 +
 +{{ :wiki:02_hiq-hotel:01_grms:s-rms_search_codes.svg |}}
 +
 +</WRAP>
 +
 +<WRAP column>
 +\\ 
 +|<300px 50px >|
 +^  1  | Enter access code.                   |
 +^  2  | Click button Search                  |
 +^  3  | Click on row to go to code details.  |
 +
 +</WRAP>
 +</WRAP>
 +
 +===== User Accounts =====
 +
 +<WRAP group>
 +<WRAP 1000px column>
 +
 +{{ :wiki:02_hiq-hotel:01_grms:s-rms_users.svg |}}
 +
 +</WRAP>
 +
 +<WRAP column>
 +\\ 
 +|<300px 50px >|
 +^  1   | Click to add new user.                              |
 +^  2   | Edit selected user.                                 |
 +^  3   | Delete selected user.                               |
 +^  4   | Users table. Click on row to select user.           |
 +^  5   | User full name (Dispalayed on top of the screen.)   |
 +^  6   | Username.                                           |
 +^  7   | Password.                                           |
 +^  8   | Re-type password.                                   |
 +^  9   | Chack for admin users.                              |
 +^  10  | Chack to enable API access.                         |
 +^  11  | Select to which controller (room) user has access.  |
 +^  12  | Cancel or Save user.                                |
 +
 +</WRAP>
 +</WRAP>