hiq_components:wr-5 [2023/12/12 07:43] alen.mejakhiq_components:wr-5 [2023/12/12 08:19] (current) alen.mejak
Line 34: Line 34:
 |      |                              05 – write single coil |  |      |                              05 – write single coil | 
 |      |                              15 – write multiple coils | |      |                              15 – write multiple coils |
- Radio   + 
-| Frequency band:                               868MHz (EU), 915MHz (US) +RELAY OUTPUT 
-| Modulation          |      FSK80kHz bandwidth |+| Nominal rating:          |                       5A 250VAC resistive | 
 +| Timeout:    |                                    24h (reset if no messages) | 
 + 
 +TEMPERATURE SENSOR 
 +| Input type:                               ES digital sensor DS18B20 | 
 +| Connection protocol:                               1-wire digital thermometer | 
 +| Sensor error          |      -1000: missing, -1001: short | 
 +| Measuring range          -50..+125°C | 
 +| Accuracy    |      ±0.5°C (-10°C to +85°C) | 
 +| Cable length    |      50m, UTP 0.25..0.5mm2 | 
 + 
 + RADIO 
 +| Frequency band:                               ISM 868MHz (EU) 
 +| Subband:                               L 866.8MHz25mW, 1% utility 
 +| Modulation          |      FSK 38.4kbps 80kHz bandwidth |
 | Group address          32-bit, automatically generated | | Group address          32-bit, automatically generated |
-Connection time    |      10s power-on to network ready | +Listen before talk    |      yes, delay limited to 20ms | 
-Output power         25mW | +| Startup time    |      10s power-on to network ready | 
-| Minimum distance    |      3m between devices |+Message delay         5ms from tx start to relay on |
 | Operating range        300m with optical visibility | | Operating range        300m with optical visibility |
 +| Output power        25mW |
  
- General + GENERAL 
-| Power supply                               230V, 50..60Hz, 2W +| Power supply                               230V, 50..60Hz, 3.5W 
-| Terminals          |      0.25..1.5mm2 | +| Terminals          |      0.25..2.5mm2 | 
-|Operating conditions        |               -20..+40°C, 0..85% rh nc |+|Operating conditions        |               -20..+50°C, 0..85% rh nc |
 |Storage temperature                  -40..+85°C | |Storage temperature                  -40..+85°C |
-|Weight             |  80g |+|Weight             |  220g |
 |Degree of protection      |    IP20 | |Degree of protection      |    IP20 |
-|Standards            EN60730-1, EN300-220-2 |+|Standards            EN60730-1, EN300-220-2, EN 301 489-1, EN 301 489-3 | 
  
  
hiq_components/wr-5.1702367008.txt.gz · Last modified: 2023/12/12 07:43 by alen.mejak