User Tools

Site Tools


hiq:components:lc-dc2

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
hiq:components:lc-dc2 [2025/02/17 10:19] – created alen.mejakhiq:components:lc-dc2 [2025/02/17 11:25] (current) – [Features] alen.mejak
Line 1: Line 1:
 ====== LC-DC2 ====== ====== LC-DC2 ======
  
-** Voltage inputs12 x 0...10V **+** IEX-2 moduleDALI-2 application controller **
  
 <WRAP column 450px> <WRAP column 450px>
  
-{{hiq_components:aiv-12_main_picture.jpg}}+{{hiq_components:lc-dc2_mainpicture.png}}
  
 </WRAP> </WRAP>
Line 23: Line 23:
  
       * IEX-2 module       * IEX-2 module
-      * 12 analog inputs 0...10V+      * DALI-2 application controller 
 +      * DALI-2 multi-master 
 +      * send and receive DALI power supply 
 +      * 10 digital inputs 
 +      * autoaddress
              
            
Line 33: Line 37:
 ===== Technical specification ===== ===== Technical specification =====
  
-Input type               |   0..10V+DALI output current               |   100mA
-Input resistance          10K+Ballasts per device          32 (2mA per device)
-|A/D converter   |                         V/f conversion with auto calibration+|Bus length   |                         200m
-|Resolution                              13 bits in 0.1% mode+|Galvanic isolation                              no
-| |                         11 bits in 0.5% and 1% mode+Autoaddress|                         yes
-Temperature drift                              +-0.01%/°C of measuring range+Typical usage                              smart home
-Scan time               |                         30ms..980ms, depends on input mode+Duty cycle               |                         1:10 (DALI active 10% of the time)
-Integration time                 |                     60ms/20ms, depends on input mode+Load protection                 |                     short-circuit and thermal shutdown
-Calibration reference                                  10.000V+|230V tolerance                                  no| 
- Power supply                 |                   24V (18..28V), 50mA| +|Input type                                   dry contact, internal pull-up 12V 2mA
-| Galvanic isolation                               1kV between digital and analog circuit| +| Power supply             |                   24V (18..28V), 200mA
-|                  |                   no isolation between chanels+|Operating conditions|                   0..45°C, 0..95% rh non-condensing| 
-| Operating conditions                  |                   0..50°C, 0..85% rh non-condensing| +Storage temperature                                    -20..75°C|
-Weight                                    160g|+
 | Degree of protection                  |                   IP20| | Degree of protection                  |                   IP20|
-Level of ambient pollution                |                   2+Weight                  |                   120g
-| Standards                |                   EN 61010-1, EN 61010-2-201, EN 61131-2|+| Standards                |                   EN 60730-1, EN 61000-4-4|
  
 ===== Terminals ===== ===== Terminals =====
Line 57: Line 60:
 <WRAP column 950px> <WRAP column 950px>
  
-{{hiq_components:aiv-12_terminals.png}} +{{hiq_components:lc-dc2_terminals.png}} 
  
 </WRAP> </WRAP>
hiq/components/lc-dc2.1739787559.txt.gz · Last modified: 2025/02/17 10:19 by alen.mejak