| Line 1: | Line 1: | ||
| + | ====== PS-IQ ====== | ||
| + | |||
| + | **24 V DC / 3.8 A power supply** | ||
| + | |||
| + | <WRAP column 400px> | ||
| + | |||
| + | {{ hiq_components: | ||
| + | |||
| + | </ | ||
| + | |||
| + | <WRAP column 300px> | ||
| + | |||
| + | | Model number: ^ PS-IQ | | ||
| + | | Mounting: | ||
| + | | Dimensions: | ||
| + | |||
| + | ===== Highlights & Features ===== | ||
| + | |||
| + | * Protection Class II, Double Isolation (No Earth connection is required) | ||
| + | * Universal AC input voltage and full power up to 55°C | ||
| + | * Power will not de-rate for the entire input voltage range | ||
| + | * Efficiency > 88.0% @ 115Vac & 230Vac | ||
| + | * NEC Class 2 / Limited Power Source (LPS) certified | ||
| + | * Over-voltage / Overcurrent / Over Temperature Protections | ||
| + | |||
| + | </ | ||
| + | |||
| + | <WRAP clear></ | ||
| + | |||
| + | ===== Safety standards ===== | ||
| + | |||
| + | CB Certified for worldwide use | ||
| + | TUV to EN 60950-1, UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1, CB scheme to IEC 60950-1, Limited Power Source (LPS) | ||
| + | |||
| + | <WRAP pagebreak></ | ||
| + | |||
| + | ===== Technical specification ===== | ||
| + | |||
| + | | Input voltage range | ||
| + | | Output voltage | ||
| + | | Output current | ||
| + | | Input current | ||
| + | | Max Inrush Current (Cold Start) | < 30A @ 115Vac, < 60A @ 230Vac | | ||
| + | | Operating temperature | ||
| + | | Storage temperature | ||
| + | |||