 +====== EL-B ======
 +==== Electromechanical strike lock, basic ====
 +<WRAP column 350px>
 +
 +{{hiq_components:dsc_0581.jpg?200|}}
 +
 +</WRAP>
 +
 +<WRAP column 300px>
 +
 +| Model number:  ^ EL-B  ^
 +
 +</WRAP>
 +<WRAP clear></WRAP>
 +
 +
 +===== General Description =====
 +
 +The EL-B is a compact electric strike, reversible flush-mounted electric strike designed for secure door access control, featuring adjustable jaw flexibility and compatibility with various AC/DC voltage ranges for reliable operation in diverse environments.
 +
 +
 +
 +===== Technical Specifications =====
 +| Installation               | Flush          |
 +| Reversible                 | Yes            |
 +| Height                     | 75 mm          |
 +| Width                      | 21 mm          |
 +| Depth                      | 28 mm          |
 +| Jaw Depth                  | 5.70 mm        |
 +| Flex Jaw Adjustment        | +4 -0 mm       |
 +| Tested Cycles              | 200,000        |
 +| Temperature Working Range  | -25°C to 50°C  |
 +| Breaking Resistance        | 3,300 N        |
 +
 +
 +
 +===== Electromechanical data =====
 +
 +| Voltage Range (V)  | Functioning       | Coil Resistance (Ω)  | Electric Duty Cycle (%ED)  | AC Current Consumption (mA)    | DC Current Consumption (mA)    | Maximum Preload Open AC  | Maximum Preload Open DC  |
 +| 24 (424) DC        | Fail Secure       | 132                  | 100% ED 24 VDC              -                             | 200                            |  -                        -                       |
 +| 24 (524) DC        | Fail Secure       | 240                  | 100% ED 24 VDC              -                             | 110                            |  -                        -                       |
 +
 +
 +Coil tolerance: ±5%
 +
 +
 +
 +
 +
 +===== Dimensions =====
 +{{hiq_components:dimension_el-b.png?600|}}
 +
 +
 +
 +
 +
 +
 +
 +
 +===== Electric and monitored Connections =====
 +
 +{{hiq_components:el-b-ms_electric.png?400|}}
 +
 +=== Electric connections ===
 +
 +  * Electric strikes work usually without polarity. A diode can be installed to work with polarity
 +
 +
 +
 +===== Installation instructions =====
 +
 +{{hiq_components:el_mounting.png?400|}}
 +
 +
 +=== Generic installation ===
 +
 +      * Before starting connection, please check the electrical features as well as the voltage and the current strenght of the power supply.
 +      * Follow the manual and connect the cable as indicated on the diagram.
 +      * Fit in the electric strike on the plate using screws.
 +      * Fit in the assembly electric strike and plate to the door frame using screws.
 +      * Adjust if it is necessary flex system.
 +      * Use the electric strike.
 +
 +=== Caution===
 +
 +Electric strike could be damaged in some wrong using conditions:
 +      * Voltage is higher than rated. Check voltage output before installation.
 +      * Do not oil or lubricate the electric strike, this could damage internal parts.
 +      * Paint, dirty or wet may aect to the electric strike functions
 +
 +===  Manufacturer Documentation ===
 +
 +Official manufacturer manual (PDF):
 +{{ hiq_components:electric_strikes_45nf_-_tech_data.pdf |}}
 +
 +  
 +