wiki:01_btms:00_hw:start [2024/03/21 09:32] – [Table] goran.kocjancicwiki:01_btms:00_hw:start [2024/04/23 13:37] – [Table] goran.kocjancic
Line 2: Line 2:
  
 |< 1200px 120px 200px 300px >| |< 1200px 120px 200px 300px >|
-^  Code                                Description                          ^  Quantity                           ^  Note                                                                                                                                                                        ^ +^  Code                                Description                                           ^  Quantity                                             ^  Note                                                                                                                                                                        ^ 
-^ Basic                               | **Required for basic functionality**                                                                                                                                                                                                                     ||| +^ Basic                               | **Required for basic functionality**                                                                                                                                                                                                                                                        ||| 
-^ [[wiki:01_btms:00_hw:01_bm-gw]]     | BTMS IOT Gateway                      | 1 × BM-GW for up to 32 strings      | All strings of one UPS should be on the same BM-GW                                                                                                                           | +^ [[wiki:01_btms:00_hw:01_bm-gw]]     | BTMS IOT Gateway                                       | 1 × BM-GW for up to 32 strings                        | All strings of one UPS should be on the same BM-GW                                                                                                                           | 
-^ [[wiki:01_btms:00_hw:02_bm-ss]]     | BTMS String master                    | 1 × BM-SS for each string           |                                                                                                                                                                              | +^ [[wiki:01_btms:00_hw:02_bm-ss]]     | BTMS String master                                     | 1 × BM-SS for each string                             |                                                                                                                                                                              | 
-^ [[wiki:01_btms:00_hw:03_bm-hs]]     | BTMS Hall sensor                      | 1 × BM-HS for each string           | Choose the type based on the maximum string current                                                                                                                          | +^ [[wiki:01_btms:00_hw:03_bm-hs]]     | BTMS Hall sensor                                       | 1 × BM-HS for each string                             | Choose the type based on the maximum string current                                                                                                                          | 
-^ [[wiki:01_btms:00_hw:04_bm-cs]]     | BTMS Cell sensor                      | 1 × BM-CS for each battery          | Choose 2, 6 or 12 V sensors depending on the battery voltage                                                                                                                 | +^ [[wiki:01_btms:00_hw:04_bm-cs]]     | BTMS Cell sensor                                       | 1 × BM-CS for each battery                            | Choose 2, 6 or 12 V sensors depending on the battery voltage                                                                                                                 | 
-^ [[wiki:01_btms:00_hw:05_bm-ps]]     | BTMS Power supply                     | 1 × PS-60-24 for each BTMS          | One power supply can power several devices, if there are fewer of them than allowed according to thespecification. Checks against the total consumption of powered devices. +^ [[wiki:01_btms:00_hw:05_bm-ps]]     | BTMS Power supply                                      | 1 × PS-60-24 for each BTMS                            | One power supply can power several devices, if there are fewer of them than allowed according to thespecification. Checks against the total consumption of powered devices. 
-^ [[wiki:01_btms:00_hw:05_ps-30-12]]  | BM-GW Power supply                    | 1 × PS-30-12 for each BM-GW         |                                                                                                                                                                              | +^ [[wiki:01_btms:00_hw:05_ps-30-12]]  | BM-GW Power supply                                     | 1 × PS-30-12 for each BM-GW                           |                                                                                                                                                                              | 
-^ Optional                            | **Depending on requirements**                                                                                                                                                                                                                            ||| +^ Optional                            | **Depending on requirements**                                                                                                                                                                                                                                                               ||| 
-^ [[wiki:01_btms:00_hw:06_bm-mc]]     | BTMS Master controller                | 1 × BM-MC for up to 32 strings      |                                                                                                                                                                              | +^ [[wiki:01_btms:00_hw:06_bm-mc]]     | BTMS Master controller                                 | 1 × BM-MC for up to 32 strings                        |                                                                                                                                                                              | 
-BM-C-A1                             | BTMS Controller set                   | 1 × BM-C-A1 for up to 32 strings    | Consisting of [[wiki:01_btms:00_hw:06_bm-mc]], [[wiki:01_btms:00_hw:07_bm-cad]] and software                                                                                 | +[[wiki:01_btms:00_hw:06_bm-c-A1]]   | BTMS Controller set                                    | 1 × BM-C-A1 for up to 32 strings                      | Consisting of [[wiki:01_btms:00_hw:06_bm-mc]], [[wiki:01_btms:00_hw:07_bm-cad]] and software                                                                                 | 
-^ [[wiki:01_btms:00_hw:07_bm-cad]]    | BTMS COM converter                    | 1 × BM-CAD per BM-HMI               |                                                                                                                                                                              | +^ [[wiki:01_btms:00_hw:07_bm-cad]]    | BTMS COM converter                                     | 1 × BM-CAD per BM-HMI                                 |                                                                                                                                                                              | 
-^ [[wiki:01_btms:00_hw:07_bm-lc]]     | BTMS IO expansion module              | 1 × BM-LC for up to 8 strings       | They require BM-MC                                                                                                                                                           | +^ [[wiki:01_btms:00_hw:07_bm-lc]]     | BTMS IO expansion module                               | 1 × BM-LC for up to 8 strings                         | They require BM-MC                                                                                                                                                           | 
-^ [[wiki:01_btms:00_hw:08_bm-th]]     | BTMS Temperature and humidity sensor  | 1 × BM-TH for every string          | They require BM-MC                                                                                                                                                           | +^ [[wiki:01_btms:00_hw:08_bm-th]]     | BTMS Temperature and humidity sensor                   | 1 × BM-TH for every string                            | They require BM-MC                                                                                                                                                           | 
-^ [[wiki:01_btms:00_hw:08_bm-gs]]     | BTMS Insulation monitoring sensor     | 1 × BM-GS for every string          | They require BM-MC                                                                                                                                                           | +^ [[wiki:01_btms:00_hw:08_bm-gs]]     | BTMS Insulation monitoring sensor                      | 1 × BM-GS for every string                            | They require BM-MC                                                                                                                                                           | 
-^ [[wiki:01_btms:00_hw:09_bm-hmi]]    | BTMS Human-Machine Interfaces         | 1 × BM-HMI-BM for up to 32 strings  | They require BM-C-A1 (BM-MC + BM-CAD), 1 per BM-C-A1                                                                                                                         | +^ [[wiki:01_btms:00_hw:09_bm-hmi]]    | BTMS Human-Machine Interfaces                          | 1 × BM-HMI-BM for up to 32 strings                    | They require BM-C-A1 (BM-MC + BM-CAD), 1 per BM-C-A1                                                                                                                         | 
-^ [[wiki:01_btms:00_hw:10_bm-ag]]     | BTMS IOT Aggregator                   | 1 × BM-AG per Data center           | Needed when there are multiple BM-GWs on the Data Center                                                                                                                     |+^ [[wiki:01_btms:00_hw:10_bm-ag]]     | BTMS IOT Aggregator                                    | 1 × BM-AG per Data center                             | Needed when there are multiple BM-GWs on the Data Center                                                                                                                     
 +^ [[wiki:01_btms:00_hw:06_th-mc]]     | Temperature and humidity monitoring Master controller  | 1 × TH-MC for up to 120 temperature-humidity sensors  |                                                                                                                                                                              |
  
 ===== System limitations ===== ===== System limitations =====