wiki:20_rdc_charger:35_commissioning:start [2023/03/31 10:11] – ↷ Links adapted because of a move operation saso.santeljwiki:20_rdc_charger:35_commissioning:start [2023/05/26 13:04] (current) – external edit 127.0.0.1
Line 1: Line 1:
 ====== Commissioning ====== ====== Commissioning ======
 +
 +when the charger is mounted (on wall or freestanding set) , properly connected, we can continue with the commissioning.
  
 Strictly follow [[wiki:20_rdc_charger:10_privacy-safety:start|Safety instructions]]! Strictly follow [[wiki:20_rdc_charger:10_privacy-safety:start|Safety instructions]]!
  
-===== Mounting =====+:!: **Once RDC Charger is configured, it does not require further connection to internet or configurator for normal operation !**
  
-Mount RDX Charger (EVSE), [[wiki:20_rdc_charger:15_hardware:20_pm1|PM1-E-D]] & [[wiki:20_rdc_charger:15_hardware:21_pm3|PM3-E-D]] power sensor as well as [[wiki:20_rdc_charger:15_hardware:22_wm-1|WM-1]] & [[wiki:20_rdc_charger:15_hardware:23_wr-1|WR-1]] to a suitable place. For more details, please read [[wiki:20_rdc_charger:15_hardware:start|Hardware]].+===== Configuration=====
  
-===== Wiring ===== +Install and run [[wiki:20_rdc_charger:30_software:start|RDC Charger]] on your PC. Use **autodetect** button to discover EVSE in local network. Enter **names**, choose **icons** for all sources and consumers
- +
-Connect EVSE to the home LAN. Wire WM-1 module with power sensor and WR-1 relay with device (e.g. heat pump, el. radiator). For more details, please read [[wiki:20_rdc_charger:25_wiring:start|Wiring]]. +
- +
-===== Configuration=====+
  
-Install and run [[wiki:20_rdc_charger:06_software:start|RDX Charger]] on your PC. Use **autodetect** button to discover EVSE in local network. Enter **names**, choose **icons** for all sources and consumers. Add WM-1 and WR-1 module by running **WM / WR binding** and press **Scan w-less dev.** for power sensors and wireless relay. 
  
 ==== Setting device management features ==== ==== Setting device management features ====
Line 23: Line 20:
   * **timetable checkbox**: enable or disable the timetable for each device.   * **timetable checkbox**: enable or disable the timetable for each device.
  
-{{wiki:rdx_charger:hems_config_consumers.png?direct&400}}+{{wiki:20_rdc_charger:hems_config_consumers.png?direct&400}}
  
 ==== Enable power sensor from compatible systems ==== ==== Enable power sensor from compatible systems ====
Line 43: Line 40:
 ==== Internet access ==== ==== Internet access ====
  
-RDX Charger is connected to the internet via IOT-L2-2 linker.+RDC Charger is connected to the internet via IOT-L2-2 linker.
  
 ==== Digital output ==== ==== Digital output ====
  
-RDX Charger is supporting up to 8 digital outputs by [[wiki:20_rdc_charger:15_hardware:23_wr-1|WR-1]] module (WR 1..WR 8). +RDC Charger is supporting up to 8 digital outputs by [[wiki:20_rdc_charger:15_hardware:23_wr-1|WR-1]] module (WR 1..WR 8). 
-  * [[wiki:20_rdc_charger:06_software:start#hems_configurator|HEMS Configurator]] -> settings page, define digital output for consumer (e.g. Digital-2 & Digital-3), +  * [[wiki:20_rdc_charger:30_software:start#hems_configurator|HEMS Configurator]] -> settings page, define digital output for consumer (e.g. Digital-2 & Digital-3), 
  
-{{wiki:rdx_charger:hems_config_digital_output.png?direct&800}}+{{wiki:20_rdc_charger:hems_config_digital_output.png?direct&800}}
  
-  * [[wiki:20_rdc_charger:06_software:start#hems_configurator|HEMS Configurator]] -> home page, toggle ON/OFF states for digital-2 and digital-3. +  * [[wiki:20_rdc_charger:30_software:start#hems_configurator|HEMS Configurator]] -> home page, toggle ON/OFF states for digital-2 and digital-3. 
  
-{{wiki:rdx_charger:hems_home_toggle_digital_output.png?direct&800}}+{{wiki:20_rdc_charger:hems_home_toggle_digital_output.png?direct&800}}
  
 **Note**: Nominal power **P nominal** is suitable for consumer(s) without connected power sensor. It is used for consumed energy calculation during active mode. **Note**: Nominal power **P nominal** is suitable for consumer(s) without connected power sensor. It is used for consumed energy calculation during active mode.
Line 61: Line 58:
 ==== IO mux ==== ==== IO mux ====
  
-[[wiki:20_rdc_charger:06_software:start#hems_configurator|HEMS Configurator]] -> IO mux page allows setting of output types for WR-1 module(s): +[[wiki:20_rdc_charger:30_software:start#hems_configurator|HEMS Configurator]] -> IO mux page allows setting of output types for WR-1 module(s): 
   * WR 1 -> to Router reset, when conditions for router reset are met, WR 1 module will change relay state (turns ON/OFF router wired to WR module),   * WR 1 -> to Router reset, when conditions for router reset are met, WR 1 module will change relay state (turns ON/OFF router wired to WR module),
   * or when WR 5 -> Digital-2, it means that change of digital2 (consumer 2) reflects on WR 5 relay state.   * or when WR 5 -> Digital-2, it means that change of digital2 (consumer 2) reflects on WR 5 relay state.
  
-{{wiki:rdx_charger:hems_io_mux_example.png?direct&400}}+{{wiki:20_rdc_charger:hems_io_mux_example.png?direct&400}}
  
 ==== Permanent memory ==== ==== Permanent memory ====
  
-[[wiki:20_rdc_charger:06_software:start#hems_configurator|HEMS Configurator]] -> settings page -> save paramenters\\  +[[wiki:20_rdc_charger:30_software:start#hems_configurator|HEMS Configurator]] -> settings page -> save paramenters\\  
-After parameters modification, it is necessary to save changes to the permanent memory since at startup RDX Charger always reads parameters from the permanent memory.+After parameters modification, it is necessary to save changes to the permanent memory since at startup RDC Charger always reads parameters from the permanent memory.
  
-{{wiki:rdx_charger:save_parameters.png?direct&500}}+{{wiki:20_rdc_charger:save_parameters.png?direct&500}}
  
 ==== Backup / restore to PC ==== ==== Backup / restore to PC ====
wiki/20_rdc_charger/35_commissioning/start.1680257516.txt.gz · Last modified: 2023/05/26 13:04 (external edit)