User Tools

Site Tools


wiki:20_rdc_charger:50_troubleshooting:start

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
wiki:20_rdc_charger:50_troubleshooting:start [2023/05/04 09:01] alen.mejakwiki:20_rdc_charger:50_troubleshooting:start [2023/05/26 13:04] – external edit 127.0.0.1
Line 1: Line 1:
 ===== Troubleshooting ===== ===== Troubleshooting =====
  
 +<WRAP column 950px>
 +RDC Charger recovers error automatically. 
 +To delete error by yourself long press button on charger housing or on application. **Charging is stopped while error is active.** **If red light still flashes, please read table bellow.**
  
-**ERROR**        | **POSSIBLE CAUSES**           | **SOLUTION**                                       +|<100% 25% 35%>| 
-|CP positive/negative voltage            |The voltage on the CP connector is out of permitted range| Check the charging cable and connector and reconnect the electric vehicle                                  +^ Error ^Possible causes ^ Possible solution ^ 
-|RCD sensor trip| Switch has detected a DC differential current               If is problem with only one vehicle, please call an authorized vehicle service| +|CP positive voltage\\ CP negative voltage |Measured voltage on CP pin is out of range| Check your charging cable and plug. Reconnect your EV. If error still appears, please contact your EVSE service.  
-|RCD sensor malfunction | RCD is damaged or not connected               | Please call  service of the charger                                                 +|RCD sensor trip                  | DC current leak detected. Please try to connect another EV, if error still appears, please contact your EVSE service. Otherwise, please contact an authorized car service department. 
-|Undervoltage/Overvoltage          The voltage at the input of the charger is out of permitted range           | Please call  service of the charger                                                +|RCD sensor malfunction           | RCD sensor is damaged or not connected| Please contact your EVSE service
-| Charge with ventilation| The vehicle requires charging with ventilation and Charging with ventilation” is not enabled on the user interface  WEnable "Charging with ventilation" on the user interface if the electric vehicle is charged  in ventilated area or outdoor                              +|Undervoltage\\ Overvoltage       Supply voltage is out of range.  | Please contact your EVSE installer. 
-Communication  LAN               RJ45                                                 +|Charge with ventilation          EV requests charging with ventilation and "Charging with ventilationis not enabled on configurator Enable "Allow charging with ventilation" if charged EV is located in ventilated area|  
-           WiFi              802.11b/g/                                         +|PS reading error                 No communication with internal power sensor. Please contact your EVSE service. 
-Power          Adapter           5V  3 A                                              +|Current is higher than allowed   Vehicle draws more power than allowed. |Please try to charge another EV, if error still appears, please contact your EVSE service. Otherwise, please contact an authorized car service department.| 
-|            | Battery           | Optional                                             | +|Internal temperature is too high Temperature inside of charger is too high. |Make sure charger is not exposed to direct sunlight. Please contact your EVSE installer. |  
- +</WRAP>
- +
wiki/20_rdc_charger/50_troubleshooting/start.txt · Last modified: 2024/03/11 09:00 by saso.santelj